Fibre optic cables — Duplex patch cords

Duplex fibre optic patch cords — OS2, OM3, OM4, outdoor

2-fibre cables for simultaneous bidirectional links: switch–switch, switch–server, ODF–active equipment. LC/UPC, LC/APC, SC/APC, FC, ST — single-mode OS2 or multimode OM3/OM4, indoor or outdoor armoured.

✓ Insertion loss ≤ 0.3 dB guaranteed ✓ CE certified — Stock in France ✓ OS2 / OM3 / OM4 available ✓ 24h shipping
Duplex 2 fibres OS2 9/125 µm OM3/OM4 50/125 µm LSZH flame-retardant Steel armoured outdoor
Duplex LC/UPC–LC/UPC OS2 single-mode yellow Elfcam patch cord Duplex LC/UPC–LC/UPC multimode OM3 aqua Elfcam patch cord
Left: OS2 single-mode (yellow) — Right: OM3/OM4 multimode (aqua/violet)

Which duplex patch cord to choose?

Duplex LC/UPC OS2 single-mode patch cord — datacenter SFP switch cabling

LC/UPC · LC/APC duplex OS2

Datacenter and enterprise network standard. Compact LC connectors for SFP switches, 19" patch panels. Single-mode OS2 9/125 µm, LSZH jacket.

  • LC/UPC–LC/UPC: switches, ODF, SFP equipment
  • LC/APC–LC/APC: telecom systems sensitive to reflections
  • LC/APC–LC/UPC: mixed link between equipment
See LC/UPC · LC/APC →
Duplex LC/UPC OM3 multimode patch cord — 10G intra-rack datacenter

Multimode OM3 · OM4 duplex

Short high-density links in datacenters. Lower-cost 850 nm VCSEL modules. Light blue LSZH jacket (OM3) or violet (OM4).

  • OM3: 10G over 300 m, 40G over 100 m
  • OM4: 10G over 400 m, 100G over 150 m (MPO)
  • Compatible with SFP+ SR, SFP28 SR modules
See OM3 · OM4 →
Duplex SC/APC OS2 single-mode patch cord — FTTH telecom equipment

SC · FC · ST · E2000 duplex OS2

Large-format connectors for telecom equipment, FTTH OLT, industrial routers and legacy hardware. Single-mode OS2.

  • SC/APC–SC/APC: OLT, ODF, FTTH equipment
  • FC/PC: measurement instruments (OTDR), older routers
  • ST/UPC: legacy 100BASE-FX Ethernet networks
See SC · FC · ST →
Steel armoured outdoor duplex LC/UPC OS2 inter-building patch cord

Outdoor reinforced duplex

Steel armour or 5 mm PE jacket for inter-building links, campus, industrial environments. OS2 or OM3 depending on distance.

  • Rodent, UV resistance, −40 °C to +85 °C
  • 5 mm diameter — tensile strength ≥ 600 N
  • Installation in trunking, cable tray, conduit
See Outdoor reinforced →

Quick decision matrix

My use case Recommended fibre Recommended connector Section
SFP switch ↔ patch panel or switch OS2 single-mode LC/UPC–LC/UPC LC OS2 ↓
OLT GPON / XGS-PON ↔ ODF OS2 single-mode SC/APC–SC/APC or LC/APC–LC/APC SC ↓
Server ↔ ToR datacenter switch (≤ 300 m) Multimode OM3 LC/UPC–LC/UPC OM3 ↓
Server ↔ ToR datacenter switch (≤ 400 m) Multimode OM4 LC/UPC–LC/UPC OM4 ↓
Outdoor inter-building (> 100 m) OS2 outdoor armoured LC/UPC–LC/UPC Outdoor ↓
Measurement instrument (OTDR) ↔ network OS2 single-mode FC/PC–SC/APC or FC/PC–LC/UPC FC ↓
Outdoor OM3 campus network (≤ 300 m) OM3 outdoor armoured LC/UPC–LC/UPC Outdoor ↓

LC duplex patch cords — single-mode OS2

Compact LC format (1.25 mm) — reference standard for SFP/SFP+/SFP28 equipment. Single-mode OS2 9/125 µm, insertion loss ≤ 0.3 dB, return loss ≥ 50 dB (UPC) / ≥ 65 dB (APC). LSZH jacket.

SC, FC, ST, E2000 duplex patch cords — single-mode OS2

Large-format SC (2.5 mm), FC (screw-on), ST (bayonet) and E2000 (protective shutter) connectors for telecom equipment, GPON/EPON OLT, ODF, measurement instruments and legacy hardware. Single-mode OS2.

SC/APC · SC/UPC duplex OS2

FC, ST, E2000 duplex OS2

Multimode duplex patch cords — OM3 and OM4

50/125 µm fibre for short high-density datacenter links. 850 nm VCSEL modules. OM3 (aqua jacket, 2,000 MHz·km) for 10G/300 m — OM4 (violet jacket, 4,700 MHz·km) for 10G/400 m and 100G/150 m.

Reinforced duplex patch cords — outdoor and industrial

Braided steel armour or 5.0 mm PE jacket. Rodent, UV and temperature resistance from −40 °C to +85 °C. For inter-building links, campus, industrial environments and mixed cable tray runs.

Duplex vs simplex: when to use a duplex patch cord?

Duplex = 2 fibres in the same jacket

A duplex patch cord contains two fibres side by side in a zip-cord (ribbed) jacket or a shared round jacket. It enables simultaneous transmission in both directions on two separate fibres — one fibre per direction.

  • Use: standard full-duplex links (Ethernet, FC, SONET)
  • Connectors: two ferrules at each end (twin connector side by side)
  • Marking: fibre A (Tx) and fibre B (Rx) distinguished by colour or marking

When to prefer simplex?

A simplex patch cord contains a single fibre. It is used when the signal only travels in one direction, or when both directions use different wavelengths on a single fibre (BiDi/WDM technology).

  • Use: BiDi SFP modules, FTTH subscriber links (SC/APC), GPON connections
  • Advantage: thinner, less bulk in congested conduits
  • See: Elfcam simplex patch cords →

Typical architecture with duplex patch cords

ServerSFP+ port
Duplex OS2LC/UPC–LC/UPC
Patch panelODF 19"
OM4 segmentMPO or duplex
ToR SwitchSFP28 25G port

Compatibility table — connectors and applications

Connector Fibre Polish Return loss Max 10G distance Typical application
LC/UPC–LC/UPC OS2 single-mode UPC (flat) ≥ 50 dB 10 km (LR) SFP+ switches, ODF, datacenter
LC/APC–LC/APC OS2 single-mode APC (8°) ≥ 65 dB 10 km (LR) Telecom, DWDM, high-reflection systems
LC/UPC–LC/UPC Multimode OM3 UPC (flat) ≥ 20 dB 300 m (SR) Intra-rack datacenter, 10G SAN
LC/UPC–LC/UPC Multimode OM4 UPC (flat) ≥ 20 dB 400 m (SR) High-density datacenter 10/25/100G
SC/APC–SC/APC OS2 single-mode APC (8°) ≥ 65 dB 10 km (LR) OLT GPON/EPON, telecom ODF
SC/APC–LC/UPC OS2 single-mode APC/UPC mixed ≥ 50 dB 10 km (LR) Transition from SC ODF to LC switch
FC/PC–FC/PC OS2 single-mode PC (flat) ≥ 40 dB 10 km (LR) OTDR measurement instruments, older routers
ST/UPC–LC/UPC OS2 single-mode UPC (flat) ≥ 40 dB 10 km (LR) Transition from 100BASE-FX ST to LC equipment
E2000/APC–LC/APC OS2 single-mode APC (8°) ≥ 65 dB 10 km (LR) Deutsche Telekom, Swisscom equipment
LC/UPC armoured–LC/UPC armoured OS2 outdoor UPC (flat) ≥ 50 dB 10 km (LR) Inter-building, campus, industrial

Compatibility with Elfcam SFP modules

LC OS2 duplex patch cords are compatible with all Elfcam SFP+ LR (10G, 1310 nm) and SFP28 LR (25G, 1310 nm) modules. OM3/OM4 patch cords are compatible with SFP+ SR (10G, 850 nm) and SFP28 SR (25G, 850 nm) modules.

See Elfcam SFP modules →

Duplex polarity and orientation

On a standard duplex patch cord, the two fibres are crossed in TIA-568 Type A (fibre 1 on end A connected to fibre 1 on end B). Check the polarity of your infrastructure if you use cords with an MPO distribution cable.

See polarity adapters →

Frequently asked questions — duplex patch cords

1Which duplex patch cord to choose for my SFP+ switch?

For a switch with SFP+ ports and LR modules (10G single-mode): choose a LC/UPC–LC/UPC OS2 duplex patch cord. This is the standard connector on all SFP+ LR modules. If your switch has SR modules (multimode 850 nm): choose LC/UPC–LC/UPC OM3 or OM4 duplex depending on distance (300 m for OM3, 400 m for OM4). Always check the type of module installed in your switch before ordering.

2What is the difference between LC/UPC and LC/APC on a duplex patch cord?

LC/UPC (blue): flat-polished face, return loss ≥ 50 dB — standard for active equipment (switches, servers, SFP modules). LC/APC (green): 8°-polished face, return loss ≥ 65 dB — required for telecom systems sensitive to reflections (DWDM, optical amplifiers, some OLTs). Warning: LC/UPC and LC/APC are not interchangeable — connecting them together creates additional insertion loss and degrades the link.

3Can a duplex OS2 patch cord be used with a multimode OM3 module?

No. Single-mode OS2 (9 µm) and multimode OM3/OM4 (50 µm) fibres have incompatible core diameters. A SFP+ SR module (multimode) connected to an OS2 fibre will generate 10 to 20 dB of insertion loss — the link will be non-functional. Always use a patch cord whose fibre type matches the module: OS2 for LR/LX modules (1310/1550 nm), OM3/OM4 for SR modules (850 nm).

4How can you visually tell an OS2 patch cord from an OM3 or OM4?

By the jacket colour: yellow = OS2 single-mode, aqua/light blue = OM3 multimode, violet/magenta = OM4 multimode, orange = OM1/OM2 (obsolete). The colour of the LC connector also confirms: blue connector = UPC (single-mode or multimode), green connector = APC (single-mode only). These colour codes are defined by TIA-598.

5What length of duplex patch cord should I order?

Measure the actual distance between the two devices along the cable path (not in a straight line), then add 10 to 20% as margin for bends and routes. Avoid patch cords that are too long: excess cable coiled in a rack increases bending losses and bulk. Typically: 0.5 to 1 m for switch–server within a rack, 2 to 5 m to link two adjacent racks, 5 to 10 m to link two distant racks or cross a room.

6Are Elfcam patch cords certified for carrier networks?

Elfcam patch cords are manufactured to IEC 61755-2-1 (connector characteristics) and IEC 61300-3-35 (ferrule cleanliness) standards. Key parameters are guaranteed: insertion loss ≤ 0.3 dB, return loss ≥ 50 dB (UPC) / ≥ 65 dB (APC), resistance to 500+ mating cycles. Our products are certified CE, RoHS and REACH. For specific carrier certifications (Orange, SFR), please consult our sales team.

7What is the difference between a duplex patch cord and an MPO trunk cable?

A duplex patch cord contains 2 fibres in a jacket and is suitable for point-to-point links at low bitrate or for individual server-switch connections in a datacenter. An MPO trunk cable (12, 24 or 48 fibres) in a single connector is used for high-density links in datacenters: one MPO-12 cable is equivalent to 6 simultaneous duplex patch cords and supports aggregate bitrates of 40, 100 or 400 Gbit/s. See Elfcam MPO cables →.

8What are the delivery times for Elfcam duplex patch cords?

All Elfcam duplex patch cords (LC/UPC OS2, LC/APC OS2, SC/APC OS2, OM3, OM4, armoured outdoor) are available in stock in France with shipping within 24 working hours. Orders placed before 2:00 pm are shipped the same day. For structured cabling projects in large quantities, tiered pricing and guaranteed delivery times are available on request via our contact form.

EN / EUR Austria
Select the country/region, the language, and the currency in which you want to shop.
Lieferung in
Austria
Wählen Sie Ihre Lieferadresse, um Versandkosten und Lieferzeit zu schätzen.
Warenkorb
Mon Panier
Chargement...